Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
Capacity | 10kVA / 9kW | |
Model | HANOVER-LX3310 | |
Brand |
| |
Brand Origin | India / China / Spain | |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Voltage Range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency Range | 50/60Hz (±5%) |
Range Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥90.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×32Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <58dB |
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
RATED POWER | 15kVA / 13.5kW |
Model | HANOVER-LX3315 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Operating voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Operating frequency range | 50/60Hz (±5%) |
Range Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
Harmonic Distortion (THDv) | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥90.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×32Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <58dB |
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
Capacity | 20kVA / 18kW |
Model | HANOVER-LX3320 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Operating voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥90.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×32Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <58dB |
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Capacity | 30kVA / 24kW |
Model | HANOVER-LX3330 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥90.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×32Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <58dB |
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Capacity | 40kVA / 36kW |
Model | HANOVER-LX3340 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Operating voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥90.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×32Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <58dB |
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Capacity | 60kVA / 54kW |
Model | HANOVER-LX3360 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
Harmonic Distortion (THDv) | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥91.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×32Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <65dB |
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Capacity | 80kVA / 72kW |
Model | HANOVER-LX3380 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Range Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥91.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×32Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <65dB |
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Capacity | 100kVA / 90kW |
Model | HANOVER-LX33100 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:1 |
Voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Range Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥91.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 432Vdc |
Number of Battery | 12V×36Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <65dB |
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Capacity | 120kVA / 108kW |
Model | HANOVER-LX33120 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Range Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥91.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 480Vdc |
Number of Battery | 12V×40Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <65dB |
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-160kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network managemen
Capacity | 160kVA / 144kW |
Model | HANOVER-LX33160 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥91.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 384Vdc |
Number of Battery | 12V×40Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |
Noise level | <65dB |
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Status | Call For Price |
3:3 Phase ONLINE UPS
Transformer Based Industrial
Embedded with isolated transformer, UID three-phase UPS solution raging from 10kva-200kva are designed for harsh environment especially industrial application. With a high-power factor up to 0.97,full DSP control and online double-conversion design, it can offer high levels of reliability and protection for industrial facilities and mission-critical systems, ensuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management, self-test & flexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk-in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Capacity | 200kVA / 180kW |
Model | HANOVER-LX33200 |
Brand | MICROTEK / KSTAR / EAST / ZIGOR |
Brand Origin | India / China / Spain |
Technology | Online Transformer Based Industrial UPS |
Phase | 3:3 |
Voltage range | 380/400/415Vac (-25% / +20%), (3Ph+N+PE) |
Frequency range | 50/60Hz (±5%) |
Range Power Factor | >0.97 (with filter) |
Output Voltage | 380/400/415Vac (±1%) |
Output frequency | 50/60Hz (±0.05%) |
THDv | <3% with linear load |
Crest factor | 3:1 (max) |
Efficiency | ≥91.5% |
Rated voltage | 380/400/415Vac |
Rated frequency | 50/60Hz(auto-sensing) |
Voltage protection range | Upper limit: +20% (+10%, +15%, +20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
Frequency protection range | ±10% (±2.5%, ±5%, ±10%, ±20% adjustable) |
Battery Voltage | 480Vdc |
Number of Battery | 12V×40Pcs |
Operating Temperature | 0~40°C |
Storage Temperature | -25℃~55℃ |
Humidity Range | 0~95% (Non-condensing) |
Altitude | <1500m |